Reinforcing content

 

 

Reinforcing content of various slab types

Slabs are cast in lengths of 1000 to 8 200mm in 100mm increments. Slabs are cast with standard steel reinforcing top and bottom dependant on the length of the slab.

Slab Type

Slab length

(mm)

Top steel

Qty/Dia

Bottom steel

Qty/Dia

C

1000-3400

3xø8mm

5xø8mm

D

3500-3800

3xø8mm

6xø8mm

E

3900-4200

3xø8mm

8xø8mm

H

4300-4600

3xø8mm

6xø12mm

H3

4700-5700

3xø8mm

9xø12mm

X

5800-7700

3xø8mm

9xø12mm

Z

7800

7xø8mm

9xø12mm

EK

5500-7400

3xø8mm

8xø8mm

EZ

7500-8200

7xø8mm

8xø8mm

Note: Echo slabs have a fixed depth of 150mm. The overall depth is increased by the thickness of the structural topping required